RM Mappings
COMPOSITION
See RM specification of the COMPOSITION class.
{
"conformance-ehrbase.de.v0/language|code": "en",
"conformance-ehrbase.de.v0/language|terminology": "ISO_639-1",
"conformance-ehrbase.de.v0/territory|code": "US",
"conformance-ehrbase.de.v0/territory|terminology": "ISO_3166-1",
"conformance-ehrbase.de.v0/category|code": "433",
"conformance-ehrbase.de.v0/category|value": "event",
"conformance-ehrbase.de.v0/category|terminology": "openehr",
"conformance-ehrbase.de.v0/context/start_time": "2021-12-21T14:19:31.649613+01:00",
"conformance-ehrbase.de.v0/context/setting|code": "238",
"conformance-ehrbase.de.v0/context/setting|value": "other care",
"conformance-ehrbase.de.v0/context/setting|terminology": "openehr",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_quantity|magnitude": 65.9,
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_quantity|unit": "unit",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/time": "2021-12-21T16:02:58.0094262+01:00",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/language|code": "en",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/language|terminology": "ISO_639-1",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/encoding|code": "UTF-8",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/encoding|terminology": "IANA_character-sets",
"conformance-ehrbase.de.v0/composer|name": "Silvia Blake"
}
{
"conformance-ehrbase.de.v0/_uid": "6e3a9506-b81c-4d74-a37f-1464fb7106b2::ehrbase.org::1",
"conformance-ehrbase.de.v0/language|code": "en",
"conformance-ehrbase.de.v0/language|terminology": "ISO_639-1",
"conformance-ehrbase.de.v0/territory|code": "US",
"conformance-ehrbase.de.v0/territory|terminology": "ISO_3166-1",
"conformance-ehrbase.de.v0/category|code": "433",
"conformance-ehrbase.de.v0/category|value": "event",
"conformance-ehrbase.de.v0/category|terminology": "openehr",
"conformance-ehrbase.de.v0/context/_health_care_facility|id": "9091",
"conformance-ehrbase.de.v0/context/_health_care_facility|id_scheme": "HOSPITAL-NS",
"conformance-ehrbase.de.v0/context/_health_care_facility|id_namespace": "HOSPITAL-NS",
"conformance-ehrbase.de.v0/context/_health_care_facility|name": "Hospital",
"conformance-ehrbase.de.v0/context/_participation:0|function": "requester",
"conformance-ehrbase.de.v0/context/_participation:0|mode": "face-to-face communication",
"conformance-ehrbase.de.v0/context/_participation:0|name": "Dr. Marcus Johnson",
"conformance-ehrbase.de.v0/context/_participation:0|id": "199",
"conformance-ehrbase.de.v0/context/_participation:0|id_scheme": "HOSPITAL-NS",
"conformance-ehrbase.de.v0/context/_participation:0|id_namespace": "HOSPITAL-NS",
"conformance-ehrbase.de.v0/context/start_time": "2021-12-21T14:19:31.649613+01:00",
"conformance-ehrbase.de.v0/context/_end_time": "2021-12-21T15:19:31.649613+01:00",
"conformance-ehrbase.de.v0/context/_location": "microbiology lab 2",
"conformance-ehrbase.de.v0/context/setting|code": "238",
"conformance-ehrbase.de.v0/context/setting|value": "other care",
"conformance-ehrbase.de.v0/context/setting|terminology": "openehr",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_quantity|magnitude": 65.9,
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_quantity|unit": "unit",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/time": "2021-12-21T16:02:58.0094262+01:00",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/language|code": "en",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/language|terminology": "ISO_639-1",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/encoding|code": "UTF-8",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/encoding|terminology": "IANA_character-sets",
"conformance-ehrbase.de.v0/_link:0|type": "problem",
"conformance-ehrbase.de.v0/_link:0|meaning": "problem related note",
"conformance-ehrbase.de.v0/_link:0|target": "ehr://ehr.network/347a5490-55ee-4da9-b91a-9bba710f730e",
"conformance-ehrbase.de.v0/composer|name": "Silvia Blake",
"conformance-ehrbase.de.v0/composer|id": "1234-5678",
"conformance-ehrbase.de.v0/composer|id_scheme": "UUID",
"conformance-ehrbase.de.v0/composer|id_namespace": "EHR.NETWORK"
}
| Flat Path | Flat type | RM Path | Required | Note |
|---|---|---|---|---|
|
language |
Yes |
||
|
territory |
Yes |
||
|
category |
yes |
||
|
composer |
yes |
add ctx/composer_self:true to set composer to PARTY_SELF |
|
|
context |
yes |
||
|
links |
no |
||
|
feeder_audit |
no |
||
|
STRING |
uid.value |
no |
ADMIN_ENTRY
See RM specification of the ADMIN_ENTRY class.
{
"conformance-ehrbase.de.v0/conformance_section/conformance_admin_entry/dv_text": "DV_TEXT 56",
"conformance-ehrbase.de.v0/conformance_section/conformance_admin_entry/language|code": "en",
"conformance-ehrbase.de.v0/conformance_section/conformance_admin_entry/language|terminology": "ISO_639-1",
"conformance-ehrbase.de.v0/conformance_section/conformance_admin_entry/encoding|code": "UTF-8",
"conformance-ehrbase.de.v0/conformance_section/conformance_admin_entry/encoding|terminology": "IANA_character-sets"
}
{
"conformance-ehrbase.de.v0/conformance_section/conformance_admin_entry/dv_text": "DV_TEXT 56",
"conformance-ehrbase.de.v0/conformance_section/conformance_admin_entry/language|code": "en",
"conformance-ehrbase.de.v0/conformance_section/conformance_admin_entry/language|terminology": "ISO_639-1",
"conformance-ehrbase.de.v0/conformance_section/conformance_admin_entry/encoding|code": "UTF-8",
"conformance-ehrbase.de.v0/conformance_section/conformance_admin_entry/encoding|terminology": "IANA_character-sets",
"conformance-ehrbase.de.v0/conformance_section/conformance_admin_entry/_other_participation:0|function": "requester",
"conformance-ehrbase.de.v0/conformance_section/conformance_admin_entry/_other_participation:0|mode": "face-to-face communication",
"conformance-ehrbase.de.v0/conformance_section/conformance_admin_entry/_other_participation:0|name": "Dr. Marcus Johnson",
"conformance-ehrbase.de.v0/conformance_section/conformance_admin_entry/_other_participation:0|id": "199",
"conformance-ehrbase.de.v0/conformance_section/conformance_admin_entry/_other_participation:0|id_namespace": "HOSPITAL-NS",
"conformance-ehrbase.de.v0/conformance_section/conformance_admin_entry/_other_participation:0|id_scheme": "HOSPITAL-NS",
"conformance-ehrbase.de.v0/conformance_section/conformance_admin_entry/_other_participation:1|function": "performer",
"conformance-ehrbase.de.v0/conformance_section/conformance_admin_entry/_other_participation:1|mode": "not specified",
"conformance-ehrbase.de.v0/conformance_section/conformance_admin_entry/_other_participation:1|name": "Lara Markham",
"conformance-ehrbase.de.v0/conformance_section/conformance_admin_entry/_other_participation:1|id": "198",
"conformance-ehrbase.de.v0/conformance_section/conformance_admin_entry/_other_participation:1|id_namespace": "HOSPITAL-NS",
"conformance-ehrbase.de.v0/conformance_section/conformance_admin_entry/_other_participation:1|id_scheme": "HOSPITAL-NS",
"conformance-ehrbase.de.v0/conformance_section/conformance_admin_entry/_work_flow_id|type": "WORKFLOW",
"conformance-ehrbase.de.v0/conformance_section/conformance_admin_entry/_work_flow_id|namespace": "HOSPITAL-NS",
"conformance-ehrbase.de.v0/conformance_section/conformance_admin_entry/_work_flow_id|id": "335645",
"conformance-ehrbase.de.v0/conformance_section/conformance_admin_entry/_work_flow_id|id_scheme": "HOSPITAL-NS",
"conformance-ehrbase.de.v0/conformance_section/conformance_admin_entry/_uid":"9fcc1c70-9349-444d-b9cb-8fa817697f5e",
"conformance-ehrbase.de.v0/conformance_section/conformance_admin_entry/_link:0|type": "problem",
"conformance-ehrbase.de.v0/conformance_section/conformance_admin_entry/_link:0|meaning": "problem related note",
"conformance-ehrbase.de.v0/conformance_section/conformance_admin_entry/_link:0|target": "ehr://ehr.network/347a5490-55ee-4da9-b91a-9bba710f730e",
"conformance-ehrbase.de.v0/conformance_section/conformance_admin_entry/_feeder_audit/originating_system_audit|version_id": "final",
"conformance-ehrbase.de.v0/conformance_section/conformance_admin_entry/_feeder_audit/originating_system_audit|system_id": "orig"
}
| Flat Path | Flat type | RM Path | Required | Note |
|---|---|---|---|---|
|
language |
Yes |
||
|
territory |
Yes |
||
|
subject |
no |
will be set to PARTY_SELF if not explicitly set |
|
|
workflow_id |
no |
||
|
links |
no |
||
|
feeder_audit |
no |
||
|
STRING |
uid.value |
no |
INSTRUCTION
See RM specification of the INSTRUCTION class.
{
"conformance-ehrbase.de.v0/conformance_section/conformance_instruction/current_activity/dv_text": "DV_TEXT 45",
"conformance-ehrbase.de.v0/conformance_section/conformance_instruction/current_activity/timing": "R4/2022-01-31T10:00:00+01:00/P3M",
"conformance-ehrbase.de.v0/conformance_section/conformance_instruction/current_activity/timing|formalism": "timing",
"conformance-ehrbase.de.v0/conformance_section/conformance_instruction/dv_text": "DV_TEXT 91",
"conformance-ehrbase.de.v0/conformance_section/conformance_instruction/expiry_time": "2022-01-31T10:33:28.724259+01:00",
"conformance-ehrbase.de.v0/conformance_section/conformance_instruction/narrative": "Human readable instruction narrative",
"conformance-ehrbase.de.v0/conformance_section/conformance_instruction/language|code": "en",
"conformance-ehrbase.de.v0/conformance_section/conformance_instruction/language|terminology": "ISO_639-1",
"conformance-ehrbase.de.v0/conformance_section/conformance_instruction/encoding|code": "UTF-8",
"conformance-ehrbase.de.v0/conformance_section/conformance_instruction/encoding|terminology": "IANA_character-sets"
}
{
"conformance-ehrbase.de.v0/conformance_section/conformance_instruction/current_activity/dv_text": "DV_TEXT 45",
"conformance-ehrbase.de.v0/conformance_section/conformance_instruction/current_activity/timing": "R4/2022-01-31T10:00:00+01:00/P3M",
"conformance-ehrbase.de.v0/conformance_section/conformance_instruction/current_activity/timing|formalism": "timing",
"conformance-ehrbase.de.v0/conformance_section/conformance_instruction/current_activity/action_archetype_id": "/openEHR-EHR-CLUSTER.conformance_action.v0/",
"conformance-ehrbase.de.v0/conformance_section/conformance_instruction/dv_text": "DV_TEXT 91",
"conformance-ehrbase.de.v0/conformance_section/conformance_instruction/expiry_time": "2022-01-31T10:33:28.724259+01:00",
"conformance-ehrbase.de.v0/conformance_section/conformance_instruction/narrative": "Human readable instruction narrative",
"conformance-ehrbase.de.v0/conformance_section/conformance_instruction/_wf_definition|value": "wf_definition",
"conformance-ehrbase.de.v0/conformance_section/conformance_instruction/_wf_definition|formalism": "formalism",
"conformance-ehrbase.de.v0/conformance_section/conformance_instruction/language|code": "en",
"conformance-ehrbase.de.v0/conformance_section/conformance_instruction/language|terminology": "ISO_639-1",
"conformance-ehrbase.de.v0/conformance_section/conformance_instruction/encoding|code": "UTF-8",
"conformance-ehrbase.de.v0/conformance_section/conformance_instruction/encoding|terminology": "IANA_character-sets",
"conformance-ehrbase.de.v0/conformance_section/conformance_instruction/_other_participation:0|function": "requester",
"conformance-ehrbase.de.v0/conformance_section/conformance_instruction/_other_participation:0|mode": "face-to-face communication",
"conformance-ehrbase.de.v0/conformance_section/conformance_instruction/_other_participation:0|name": "Dr. Marcus Johnson",
"conformance-ehrbase.de.v0/conformance_section/conformance_instruction/_other_participation:0|id": "199",
"conformance-ehrbase.de.v0/conformance_section/conformance_instruction/_other_participation:0|id_namespace": "HOSPITAL-NS",
"conformance-ehrbase.de.v0/conformance_section/conformance_instruction/_other_participation:0|id_scheme": "HOSPITAL-NS",
"conformance-ehrbase.de.v0/conformance_section/conformance_instruction/_other_participation:1|function": "performer",
"conformance-ehrbase.de.v0/conformance_section/conformance_instruction/_other_participation:1|mode": "not specified",
"conformance-ehrbase.de.v0/conformance_section/conformance_instruction/_other_participation:1|name": "Lara Markham",
"conformance-ehrbase.de.v0/conformance_section/conformance_instruction/_other_participation:1|id": "198",
"conformance-ehrbase.de.v0/conformance_section/conformance_instruction/_other_participation:1|id_namespace": "HOSPITAL-NS",
"conformance-ehrbase.de.v0/conformance_section/conformance_instruction/_other_participation:1|id_scheme": "HOSPITAL-NS",
"conformance-ehrbase.de.v0/conformance_section/conformance_instruction/_guideline_id|type": "GUIDELINE",
"conformance-ehrbase.de.v0/conformance_section/conformance_instruction/_guideline_id|namespace": "HOSPITAL-NS",
"conformance-ehrbase.de.v0/conformance_section/conformance_instruction/_guideline_id|id": "3445",
"conformance-ehrbase.de.v0/conformance_section/conformance_instruction/_guideline_id|id_scheme": "HOSPITAL-NS",
"conformance-ehrbase.de.v0/conformance_section/conformance_instruction/_work_flow_id|type": "WORKFLOW",
"conformance-ehrbase.de.v0/conformance_section/conformance_instruction/_work_flow_id|namespace": "HOSPITAL-NS",
"conformance-ehrbase.de.v0/conformance_section/conformance_instruction/_work_flow_id|id": "335645",
"conformance-ehrbase.de.v0/conformance_section/conformance_instruction/_work_flow_id|id_scheme": "HOSPITAL-NS",
"conformance-ehrbase.de.v0/conformance_section/conformance_instruction/_uid":"9fcc1c70-9349-444d-b9cb-8fa817697f5e",
"conformance-ehrbase.de.v0/conformance_section/conformance_instruction/_link:0|type": "problem",
"conformance-ehrbase.de.v0/conformance_section/conformance_instruction/_link:0|meaning": "problem related note",
"conformance-ehrbase.de.v0/conformance_section/conformance_instruction/_link:0|target": "ehr://ehr.network/347a5490-55ee-4da9-b91a-9bba710f730e",
"conformance-ehrbase.de.v0/conformance_section/conformance_instruction/_feeder_audit/originating_system_audit|version_id": "final",
"conformance-ehrbase.de.v0/conformance_section/conformance_instruction/_feeder_audit/originating_system_audit|system_id": "orig"
}
| Flat Path | Flat type | RM Path | Required | Note |
|---|---|---|---|---|
|
language |
Yes |
||
|
territory |
Yes |
||
|
narrative |
yes |
||
|
expiry_time |
Yes |
||
|
wf_definition |
no |
||
|
subject |
no |
will be set to PARTY_SELF if not explicitly set |
|
|
guideline_id |
no |
||
|
workflow_id |
no |
||
|
links |
no |
||
|
feeder_audit |
no |
||
|
STRING |
uid.value |
no |
ACTION
See RM specification of the EVALUATION class.
{
"conformance-ehrbase.de.v0/conformance_section/conformance_action/dv_text": "dv_text in description",
"conformance-ehrbase.de.v0/conformance_section/conformance_action/dv_text2": "dv_text in protocol",
"conformance-ehrbase.de.v0/conformance_section/conformance_action/ism_transition/current_state|code": "532",
"conformance-ehrbase.de.v0/conformance_section/conformance_action/ism_transition/current_state|value": "completed",
"conformance-ehrbase.de.v0/conformance_section/conformance_action/ism_transition/current_state|terminology": "openehr",
"conformance-ehrbase.de.v0/conformance_section/conformance_action/time": "2022-01-31T10:33:28.72414+01:00",
"conformance-ehrbase.de.v0/conformance_section/conformance_action/language|code": "en",
"conformance-ehrbase.de.v0/conformance_section/conformance_action/language|terminology": "ISO_639-1",
"conformance-ehrbase.de.v0/conformance_section/conformance_action/encoding|code": "UTF-8",
"conformance-ehrbase.de.v0/conformance_section/conformance_action/encoding|terminology": "IANA_character-sets"
}
{
"conformance-ehrbase.de.v0/conformance_section/conformance_action/dv_text": "dv_text in description",
"conformance-ehrbase.de.v0/conformance_section/conformance_action/dv_text2": "dv_text in protocol",
"conformance-ehrbase.de.v0/conformance_section/conformance_action/ism_transition/current_state|code": "532",
"conformance-ehrbase.de.v0/conformance_section/conformance_action/ism_transition/current_state|value": "completed",
"conformance-ehrbase.de.v0/conformance_section/conformance_action/ism_transition/current_state|terminology": "openehr",
"conformance-ehrbase.de.v0/conformance_section/conformance_action/_instruction_details|path": "/content[openEHR-EHR-SECTION.conformance_section.v0]/items[openEHR-EHR-INSTRUCTION.conformance_instruction.v0]",
"conformance-ehrbase.de.v0/conformance_section/conformance_action/_instruction_details|composition_uid": "4cdc3017-d8c5-4cd3-9900-f3bb7171d006",
"conformance-ehrbase.de.v0/conformance_section/conformance_action/_instruction_details|activity_id": "activities[at0001]",
"conformance-ehrbase.de.v0/conformance_section/conformance_action/time": "2022-01-31T10:33:28.72414+01:00",
"conformance-ehrbase.de.v0/conformance_section/conformance_action/language|code": "en",
"conformance-ehrbase.de.v0/conformance_section/conformance_action/language|terminology": "ISO_639-1",
"conformance-ehrbase.de.v0/conformance_section/conformance_action/encoding|code": "UTF-8",
"conformance-ehrbase.de.v0/conformance_section/conformance_action/encoding|terminology": "IANA_character-sets",
"conformance-ehrbase.de.v0/conformance_section/conformance_action/_other_participation:0|function": "requester",
"conformance-ehrbase.de.v0/conformance_section/conformance_action/_other_participation:0|mode": "face-to-face communication",
"conformance-ehrbase.de.v0/conformance_section/conformance_action/_other_participation:0|name": "Dr. Marcus Johnson",
"conformance-ehrbase.de.v0/conformance_section/conformance_action/_other_participation:0|id": "199",
"conformance-ehrbase.de.v0/conformance_section/conformance_action/_other_participation:0|id_namespace": "HOSPITAL-NS",
"conformance-ehrbase.de.v0/conformance_section/conformance_action/_other_participation:0|id_scheme": "HOSPITAL-NS",
"conformance-ehrbase.de.v0/conformance_section/conformance_action/_other_participation:1|function": "performer",
"conformance-ehrbase.de.v0/conformance_section/conformance_action/_other_participation:1|mode": "not specified",
"conformance-ehrbase.de.v0/conformance_section/conformance_action/_other_participation:1|name": "Lara Markham",
"conformance-ehrbase.de.v0/conformance_section/conformance_action/_other_participation:1|id": "198",
"conformance-ehrbase.de.v0/conformance_section/conformance_action/_other_participation:1|id_namespace": "HOSPITAL-NS",
"conformance-ehrbase.de.v0/conformance_section/conformance_action/_other_participation:1|id_scheme": "HOSPITAL-NS",
"conformance-ehrbase.de.v0/conformance_section/conformance_action/_guideline_id|type": "GUIDELINE",
"conformance-ehrbase.de.v0/conformance_section/conformance_action/_guideline_id|namespace": "HOSPITAL-NS",
"conformance-ehrbase.de.v0/conformance_section/conformance_action/_guideline_id|id": "3445",
"conformance-ehrbase.de.v0/conformance_section/conformance_action/_guideline_id|id_scheme": "HOSPITAL-NS",
"conformance-ehrbase.de.v0/conformance_section/conformance_action/_work_flow_id|type": "WORKFLOW",
"conformance-ehrbase.de.v0/conformance_section/conformance_action/_work_flow_id|namespace": "HOSPITAL-NS",
"conformance-ehrbase.de.v0/conformance_section/conformance_action/_work_flow_id|id": "335645",
"conformance-ehrbase.de.v0/conformance_section/conformance_action/_work_flow_id|id_scheme": "HOSPITAL-NS",
"conformance-ehrbase.de.v0/conformance_section/conformance_action/_uid":"9fcc1c70-9349-444d-b9cb-8fa817697f5e",
"conformance-ehrbase.de.v0/conformance_section/conformance_action/_link:0|type": "problem",
"conformance-ehrbase.de.v0/conformance_section/conformance_action/_link:0|meaning": "problem related note",
"conformance-ehrbase.de.v0/conformance_section/conformance_action/_link:0|target": "ehr://ehr.network/347a5490-55ee-4da9-b91a-9bba710f730e",
"conformance-ehrbase.de.v0/conformance_section/conformance_action/_feeder_audit/originating_system_audit|version_id": "final",
"conformance-ehrbase.de.v0/conformance_section/conformance_action/_feeder_audit/originating_system_audit|system_id": "orig"
}
| Flat Path | Flat type | RM Path | Required | Note |
|---|---|---|---|---|
|
language |
Yes |
||
|
territory |
Yes |
||
|
time |
YES |
||
|
ism_transition |
Yes |
||
|
instruction_details |
no |
||
|
subject |
no |
will be set to PARTY_SELF if not explicitly set |
|
|
guideline_id |
no |
||
|
workflow_id |
no |
||
|
links |
no |
||
|
feeder_audit |
no |
||
|
STRING |
uid.value |
no |
EVALUATION
See RM specification of the EVALUATION class.
{
"conformance-ehrbase.de.v0/conformance_section/conformance_evaluation/dv_text": "dv_text in data",
"conformance-ehrbase.de.v0/conformance_section/conformance_evaluation/dv_text2": "dv_text in protocol",
"conformance-ehrbase.de.v0/conformance_section/conformance_evaluation/language|code": "en",
"conformance-ehrbase.de.v0/conformance_section/conformance_evaluation/language|terminology": "ISO_639-1",
"conformance-ehrbase.de.v0/conformance_section/conformance_evaluation/encoding|code": "UTF-8",
"conformance-ehrbase.de.v0/conformance_section/conformance_evaluation/encoding|terminology": "IANA_character-sets"
}
{
"conformance-ehrbase.de.v0/conformance_section/conformance_evaluation/dv_text": "dv_text in data",
"conformance-ehrbase.de.v0/conformance_section/conformance_evaluation/dv_text2": "dv_text in protocol",
"conformance-ehrbase.de.v0/conformance_section/conformance_evaluation/language|code": "en",
"conformance-ehrbase.de.v0/conformance_section/conformance_evaluation/language|terminology": "ISO_639-1",
"conformance-ehrbase.de.v0/conformance_section/conformance_evaluation/encoding|code": "UTF-8",
"conformance-ehrbase.de.v0/conformance_section/conformance_evaluation/encoding|terminology": "IANA_character-sets",
"conformance-ehrbase.de.v0/conformance_section/conformance_evaluation/_other_participation:0|function": "requester",
"conformance-ehrbase.de.v0/conformance_section/conformance_evaluation/_other_participation:0|mode": "face-to-face communication",
"conformance-ehrbase.de.v0/conformance_section/conformance_evaluation/_other_participation:0|name": "Dr. Marcus Johnson",
"conformance-ehrbase.de.v0/conformance_section/conformance_evaluation/_other_participation:0|id": "199",
"conformance-ehrbase.de.v0/conformance_section/conformance_evaluation/_other_participation:0|id_namespace": "HOSPITAL-NS",
"conformance-ehrbase.de.v0/conformance_section/conformance_evaluation/_other_participation:0|id_scheme": "HOSPITAL-NS",
"conformance-ehrbase.de.v0/conformance_section/conformance_evaluation/_other_participation:1|function": "performer",
"conformance-ehrbase.de.v0/conformance_section/conformance_evaluation/_other_participation:1|mode": "not specified",
"conformance-ehrbase.de.v0/conformance_section/conformance_evaluation/_other_participation:1|name": "Lara Markham",
"conformance-ehrbase.de.v0/conformance_section/conformance_evaluation/_other_participation:1|id": "198",
"conformance-ehrbase.de.v0/conformance_section/conformance_evaluation/_other_participation:1|id_namespace": "HOSPITAL-NS",
"conformance-ehrbase.de.v0/conformance_section/conformance_evaluation/_other_participation:1|id_scheme": "HOSPITAL-NS",
"conformance-ehrbase.de.v0/conformance_section/conformance_evaluation/_guideline_id|type": "GUIDELINE",
"conformance-ehrbase.de.v0/conformance_section/conformance_evaluation/_guideline_id|namespace": "HOSPITAL-NS",
"conformance-ehrbase.de.v0/conformance_section/conformance_evaluation/_guideline_id|id": "3445",
"conformance-ehrbase.de.v0/conformance_section/conformance_evaluation/_guideline_id|id_scheme": "HOSPITAL-NS",
"conformance-ehrbase.de.v0/conformance_section/conformance_evaluation/_work_flow_id|type": "WORKFLOW",
"conformance-ehrbase.de.v0/conformance_section/conformance_evaluation/_work_flow_id|namespace": "HOSPITAL-NS",
"conformance-ehrbase.de.v0/conformance_section/conformance_evaluation/_work_flow_id|id": "335645",
"conformance-ehrbase.de.v0/conformance_section/conformance_evaluation/_work_flow_id|id_scheme": "HOSPITAL-NS",
"conformance-ehrbase.de.v0/conformance_section/conformance_evaluation/_uid":"9fcc1c70-9349-444d-b9cb-8fa817697f5e",
"conformance-ehrbase.de.v0/conformance_section/conformance_evaluation/_link:0|type": "problem",
"conformance-ehrbase.de.v0/conformance_section/conformance_evaluation/_link:0|meaning": "problem related note",
"conformance-ehrbase.de.v0/conformance_section/conformance_evaluation/_link:0|target": "ehr://ehr.network/347a5490-55ee-4da9-b91a-9bba710f730e",
"conformance-ehrbase.de.v0/conformance_section/conformance_evaluation/_feeder_audit/originating_system_audit|version_id": "final",
"conformance-ehrbase.de.v0/conformance_section/conformance_evaluation/_feeder_audit/originating_system_audit|system_id": "orig"
}
| Flat Path | Flat type | RM Path | Required | Note |
|---|---|---|---|---|
|
language |
Yes |
||
|
territory |
Yes |
||
|
subject |
no |
will be set to PARTY_SELF if not explicitly set |
|
|
guideline_id |
no |
||
|
workflow_id |
no |
||
|
links |
no |
||
|
feeder_audit |
no |
||
|
STRING |
uid.value |
no |
OBSERVATION
See RM specification of the COMPOSITION class.
{
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_quantity|magnitude": 65.9,
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_quantity|unit": "unit",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_text_state": "DV_TEXT in State",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/dv_text": "dv_text in protocol",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/time": "2021-12-21T16:02:58.0094262+01:00",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/language|code": "en",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/language|terminology": "ISO_639-1",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/encoding|code": "UTF-8",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/encoding|terminology": "IANA_character-sets"
}
{
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_quantity|magnitude": 65.9,
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_quantity|unit": "unit",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_text_state": "DV_TEXT in State",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/dv_text": "dv_text in protocol",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/time": "2021-12-21T16:02:58.0094262+01:00",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/history_origin": "2021-12-20T16:02:58.0094262+01:00",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/language|code": "en",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/language|terminology": "ISO_639-1",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/encoding|code": "UTF-8",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/encoding|terminology": "IANA_character-sets",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/subject|id": "1234-5678",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/subject|id_scheme": "UUID",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/subject|id_namespace": "EHR.NETWORK",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/subject|name": "Silvia Blake",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/subject/_identifier:0|id": "122",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/subject/_identifier:0|issuer": "issuer",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/subject/_identifier:0|assigner": "assigner",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/subject/_identifier:0|type": "type",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/subject/relationship|code": "10",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/subject/relationship|value": "mother",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/_provider|name": "Dr. Marcus Johnson",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/_other_participation:0|function": "requester",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/_other_participation:0|mode": "face-to-face communication",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/_other_participation:0|name": "Dr. Marcus Johnson",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/_other_participation:0|id": "199",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/_other_participation:0|id_namespace": "HOSPITAL-NS",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/_other_participation:0|id_scheme": "HOSPITAL-NS",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/_other_participation:1|function": "performer",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/_other_participation:1|mode": "not specified",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/_other_participation:1|name": "Lara Markham",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/_other_participation:1|id": "198",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/_other_participation:1|id_namespace": "HOSPITAL-NS",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/_other_participation:1|id_scheme": "HOSPITAL-NS",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/_guideline_id|type": "GUIDELINE",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/_guideline_id|namespace": "HOSPITAL-NS",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/_guideline_id|id": "3445",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/_guideline_id|id_scheme": "HOSPITAL-NS",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/_work_flow_id|type": "WORKFLOW",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/_work_flow_id|namespace": "HOSPITAL-NS",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/_work_flow_id|id": "335645",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/_work_flow_id|id_scheme": "HOSPITAL-NS",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/_uid":"9fcc1c70-9349-444d-b9cb-8fa817697f5e",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/_link:0|type": "problem",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/_link:0|meaning": "problem related note",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/_link:0|target": "ehr://ehr.network/347a5490-55ee-4da9-b91a-9bba710f730e",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/_feeder_audit/originating_system_audit|version_id": "final",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/_feeder_audit/originating_system_audit|system_id": "orig",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/_feeder_audit/original_content": "Hello world!",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/_feeder_audit/original_content|formalism": "text/plain"
}
| Flat Path | Flat type | RM Path | Required | Note |
|---|---|---|---|---|
|
language |
Yes |
||
|
territory |
Yes |
||
|
history.origin |
no |
will be set to the time of the earliest event if not explicitly set |
|
|
subject |
no |
will be set to PARTY_SELF if not explicitly set |
|
|
guideline_id |
no |
||
|
workflow_id |
no |
||
|
links |
no |
||
|
feeder_audit |
no |
||
|
STRING |
uid.value |
no |
ELEMENT
See RM specification of the ELEMENT class.
|
Using FLAT format there is no difference between an ELEMENT and its value. |
{
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_quantity|magnitude": 65.9,
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_quantity|unit": "unit"
}
{
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_quantity|magnitude": 65.9,
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_quantity|unit": "unit",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_quantity/_uid":"9fcc1c70-9349-444d-b9cb-8fa817697f5e",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_quantity/_link:0|type": "problem",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_quantity/_link:0|meaning": "problem related note",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_quantity/_link:0|target": "ehr://ehr.network/347a5490-55ee-4da9-b91a-9bba710f730e",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_quantity/_feeder_audit/originating_system_audit|version_id": "final",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_quantity/_feeder_audit/originating_system_audit|system_id": "orig"
}
{
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_quantity/_null_flavour|code": "253",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_quantity/_null_flavour|value": "unknown",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_quantity/_null_flavour|terminology": "openehr",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_quantity/_null_reason": "sample reason"
}
| Flat Path | Flat type | RM Path | Required | Note |
|---|---|---|---|---|
|
null_flavour |
no |
||
|
null_reason |
no |
||
|
links |
no |
||
|
feeder_audit |
no |
||
|
STRING |
uid.value |
no |
CLUSTER
See RM specification of the CLUSTER class.
{
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/conformance_cluster/labresult/text_value": "labresult 4"
}
{
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/conformance_cluster/labresult/text_value": "labresult 4",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/conformance_cluster/_feeder_audit/originating_system_audit|version_id": "final",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/conformance_cluster/_feeder_audit/originating_system_audit|system_id": "orig",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/conformance_cluster/_uid":"9fcc1c70-9349-444d-b9cb-8fa817697f5e",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/conformance_cluster/_link:0|type": "problem",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/conformance_cluster/_link:0|meaning": "problem related note",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/conformance_cluster/_link:0|target": "ehr://ehr.network/347a5490-55ee-4da9-b91a-9bba710f730e"
}
| Flat Path | Flat type | RM Path | Required | Note |
|---|---|---|---|---|
|
links |
no |
||
|
feeder_audit |
no |
||
|
STRING |
uid.value |
no |
LINK
See RM specification of the LINK class.
{
"conformance-ehrbase.de.v0/_link:0|type": "problem",
"conformance-ehrbase.de.v0/_link:0|meaning": "problem related note",
"conformance-ehrbase.de.v0/_link:0|target": "ehr://ehr.network/347a5490-55ee-4da9-b91a-9bba710f730e"
}
| Flat Path | Flat type | RM Path | Required | Note |
|---|---|---|---|---|
|
STRING |
type.value |
yes |
|
|
STRING |
meaning.value |
yes |
|
|
STRING |
type.value |
yes |
FEEDER_AUDIT
See RM specification of the FEEDER_AUDIT class.
{
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/_feeder_audit/originating_system_audit|system_id": "orig"
}
{
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/_feeder_audit/originating_system_audit|version_id": "final",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/_feeder_audit/originating_system_audit|system_id": "orig",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/_feeder_audit/originating_system_audit/location|id": "12342341",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/_feeder_audit/originating_system_audit/location|id_namespace": "uk.org.nmc",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/_feeder_audit/originating_system_audit/location|id_scheme": "NMC",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/_feeder_audit/originating_system_audit/location|name": "Org 1",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/_feeder_audit/originating_system_audit/subject|id": "456",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/_feeder_audit/originating_system_audit/subject|id_namespace": "uk.org.nmc",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/_feeder_audit/originating_system_audit/subject|id_scheme": "NMC",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/_feeder_audit/originating_system_audit/subject|name": "Per 1",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/_feeder_audit/originating_system_audit/provider|id": "456",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/_feeder_audit/originating_system_audit/provider|id_namespace": "uk.org.nmc",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/_feeder_audit/originating_system_audit/provider|id_scheme": "NMC",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/_feeder_audit/originating_system_audit/provider|name": "Per 1",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/_feeder_audit/originating_system_audit|time": "2021-12-21T16:02:58.0094262+01:00",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/_feeder_audit/originating_system_item_id:0|id": "id1",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/_feeder_audit/originating_system_item_id:0|issuer": "issuer1",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/_feeder_audit/originating_system_item_id:0|assigner": "assigner1",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/_feeder_audit/originating_system_item_id:0|type": "PERSON",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/_feeder_audit/originating_system_item_id:1|id": "id2",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/_feeder_audit/originating_system_item_id:1|issuer": "issuer2",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/_feeder_audit/originating_system_item_id:1|assigner": "assigner2",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/_feeder_audit/originating_system_item_id:1|type": "PERSON",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/_feeder_audit/original_content": "Hello world!",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/_feeder_audit/original_content|formalism": "text/plain",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/_feeder_audit/feeder_system_item_id:0|id": "id1",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/_feeder_audit/feeder_system_item_id:0|issuer": "issuer1",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/_feeder_audit/feeder_system_item_id:0|assigner": "assigner1",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/_feeder_audit/feeder_system_item_id:0|type": "PERSON",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/_feeder_audit/feeder_system_item_id:1|id": "id2",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/_feeder_audit/feeder_system_item_id:1|issuer": "issuer2",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/_feeder_audit/feeder_system_item_id:1|assigner": "assigner2",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/_feeder_audit/feeder_system_item_id:1|type": "PERSON",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/_feeder_audit/feeder_system_audit|version_id": "final",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/_feeder_audit/feeder_system_audit|system_id": "orig",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/_feeder_audit/feeder_system_audit/location|id": "12342341",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/_feeder_audit/feeder_system_audit/location|id_namespace": "uk.org.nmc",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/_feeder_audit/feeder_system_audit/location|id_scheme": "NMC",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/_feeder_audit/feeder_system_audit/location|name": "Org 1",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/_feeder_audit/feeder_system_audit/subject|id": "456",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/_feeder_audit/feeder_system_audit/subject|id_namespace": "uk.org.nmc",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/_feeder_audit/feeder_system_audit/subject|id_scheme": "NMC",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/_feeder_audit/feeder_system_audit/subject|name": "Per 1",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/_feeder_audit/feeder_system_audit/provider|id": "456",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/_feeder_audit/feeder_system_audit/provider|id_namespace": "uk.org.nmc",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/_feeder_audit/feeder_system_audit/provider|id_scheme": "NMC",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/_feeder_audit/feeder_system_audit/provider|name": "Per 1",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/_feeder_audit/feeder_system_audit|time": "2021-12-21T16:02:58.0094262+01:00"
}
| Flat Path | Flat type | RM Path | Required | Note |
|---|---|---|---|---|
|
originating_system_item_ids |
no |
||
|
feeder_system_item_ids |
no |
||
|
original_content |
no |
one one of original_content and original_content_multimedia can be set |
|
|
original_content |
no |
one one of original_content and original_content_multimedia can be set |
|
|
originating_system_audit |
yes |
||
|
feeder_system_audit |
no |
FEEDER_AUDIT_DETAILS
See RM specification of the FEEDER_AUDIT_DETAILS class.
{
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/_feeder_audit/feeder_system_audit|system_id": "orig"
}
{
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/_feeder_audit/feeder_system_audit/subject|id": "1234-5678",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/_feeder_audit/feeder_system_audit/subject|id_scheme": "UUID",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/_feeder_audit/feeder_system_audit/subject|id_namespace": "EHR.NETWORK",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/_feeder_audit/feeder_system_audit/subject|name": "Silvia Blake",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/_feeder_audit/feeder_system_audit/subject/_identifier:0|id": "122",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/_feeder_audit/feeder_system_audit/subject/_identifier:0|issuer": "issuer",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/_feeder_audit/feeder_system_audit/subject/_identifier:0|assigner": "assigner",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/_feeder_audit/feeder_system_audit/subject/_identifier:0|type": "type",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/_feeder_audit/feeder_system_audit/provider|id": "1234-5678",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/_feeder_audit/feeder_system_audit/provider|id_scheme": "UUID",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/_feeder_audit/feeder_system_audit/provider|id_namespace": "EHR.NETWORK",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/_feeder_audit/feeder_system_audit/provider|name": "Silvia Blake",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/_feeder_audit/feeder_system_audit/provider/_identifier:0|id": "122",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/_feeder_audit/feeder_system_audit/provider/_identifier:0|issuer": "issuer",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/_feeder_audit/feeder_system_audit/provider/_identifier:0|assigner": "assigner",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/_feeder_audit/feeder_system_audit/provider/_identifier:0|type": "type",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/_feeder_audit/feeder_system_audit/location|id": "12342341",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/_feeder_audit/feeder_system_audit/location|id_scheme": "NMC",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/_feeder_audit/feeder_system_audit/location|id_namespace": "uk.org.nmc",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/_feeder_audit/feeder_system_audit/location|name": "Org 1",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/_feeder_audit/feeder_system_audit|system_id": "orig",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/_feeder_audit/feeder_system_audit|version_id": "final",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/_feeder_audit/feeder_system_audit|time": "2021-12-21T16:02:58.0094262+01:00"
}
| Flat Path | Flat type | RM Path | Required | Note |
|---|---|---|---|---|
|
String |
system_id |
yes |
|
|
String |
version_id |
no |
|
|
String |
time.value |
no |
|
|
subject |
no |
add /subject|_type:"PARTY_SELF" to set this to PARTY_SELF |
|
|
provider |
no |
||
|
location |
no |
ACTIVITY
See RM specification of the ACTIVITY class.
{
"conformance-ehrbase.de.v0/conformance_section/conformance_instruction/current_activity/dv_text": "DV_TEXT 45",
"conformance-ehrbase.de.v0/conformance_section/conformance_instruction/current_activity/timing": "R4/2022-01-31T10:00:00+01:00/P3M",
"conformance-ehrbase.de.v0/conformance_section/conformance_instruction/current_activity/timing|formalism": "timing"
}
{
"conformance-ehrbase.de.v0/conformance_section/conformance_instruction/current_activity/dv_text": "DV_TEXT 45",
"conformance-ehrbase.de.v0/conformance_section/conformance_instruction/current_activity/timing": "R4/2022-01-31T10:00:00+01:00/P3M",
"conformance-ehrbase.de.v0/conformance_section/conformance_instruction/current_activity/timing|formalism": "timing",
"conformance-ehrbase.de.v0/conformance_section/conformance_instruction/current_activity/action_archetype_id": "/openEHR-EHR-CLUSTER.conformance_action.v0/"
}
| Flat Path | Flat type | RM Path | Required | Note |
|---|---|---|---|---|
|
timing |
no |
||
|
STRING |
action_archetype_id |
no |
Will be set to /.*/ if not set explicit. |
ISM_TRANSITION
See RM specification of the ACTIVITY class.
{
"conformance-ehrbase.de.v0/conformance_section/conformance_action/ism_transition/current_state|code": "532",
"conformance-ehrbase.de.v0/conformance_section/conformance_action/ism_transition/current_state|value": "completed",
"conformance-ehrbase.de.v0/conformance_section/conformance_action/ism_transition/current_state|terminology": "openehr"
}
{
"conformance-ehrbase.de.v0/conformance_section/conformance_action/ism_transition/current_state|code": "532",
"conformance-ehrbase.de.v0/conformance_section/conformance_action/ism_transition/current_state|value": "completed",
"conformance-ehrbase.de.v0/conformance_section/conformance_action/ism_transition/current_state|terminology": "openehr",
"conformance-ehrbase.de.v0/conformance_section/conformance_action/ism_transition/transition|code": "548",
"conformance-ehrbase.de.v0/conformance_section/conformance_action/ism_transition/transition|value": "finish",
"conformance-ehrbase.de.v0/conformance_section/conformance_action/ism_transition/transition|terminology": "openehr",
"conformance-ehrbase.de.v0/conformance_section/conformance_action/ism_transition/careflow_step|code": "at0006",
"conformance-ehrbase.de.v0/conformance_section/conformance_action/ism_transition/careflow_step|value": "transition",
"conformance-ehrbase.de.v0/conformance_section/conformance_action/ism_transition/careflow_step|terminology": "local",
"conformance-ehrbase.de.v0/conformance_section/conformance_action/ism_transition/_reason:0": "reason 1"
}
| Flat Path | Flat type | RM Path | Required | Note |
|---|---|---|---|---|
|
current_state |
yes |
||
|
transition |
no |
||
|
careflow_step |
no |
||
|
reason |
no |
INSTRUCTION_DETAILS
See RM specification of the INSTRUCTION_DETAILS class.
{
"conformance-ehrbase.de.v0/conformance_section/conformance_action/_instruction_details|path": "/content[openEHR-EHR-SECTION.conformance_section.v0]/items[openEHR-EHR-INSTRUCTION.conformance_instruction.v0]",
"conformance-ehrbase.de.v0/conformance_section/conformance_action/_instruction_details|composition_uid": "4cdc3017-d8c5-4cd3-9900-f3bb7171d006",
"conformance-ehrbase.de.v0/conformance_section/conformance_action/_instruction_details|activity_id": "activities[at0001]"
}
| Flat Path | Flat type | RM Path | Required | Note |
|---|---|---|---|---|
|
STRING |
instruction_id.path |
yes |
|
|
STRING |
instruction_id.id |
yes |
|
|
STRING |
activity_id |
yes |
EVENT_CONTEXT
See RM specification of the EVENT_CONTEXT class.
{
"conformance-ehrbase.de.v0/context/start_time": "2021-12-21T14:19:31.649613+01:00",
"conformance-ehrbase.de.v0/context/setting|code": "238",
"conformance-ehrbase.de.v0/context/setting|value": "other care",
"conformance-ehrbase.de.v0/context/setting|terminology": "openehr"
}
{
"conformance-ehrbase.de.v0/context/_health_care_facility|id": "9091",
"conformance-ehrbase.de.v0/context/_health_care_facility|id_scheme": "HOSPITAL-NS",
"conformance-ehrbase.de.v0/context/_health_care_facility|id_namespace": "HOSPITAL-NS",
"conformance-ehrbase.de.v0/context/_health_care_facility|name": "Hospital",
"conformance-ehrbase.de.v0/context/_participation:0|function": "requester",
"conformance-ehrbase.de.v0/context/_participation:0|mode": "face-to-face communication",
"conformance-ehrbase.de.v0/context/_participation:0|name": "Dr. Marcus Johnson",
"conformance-ehrbase.de.v0/context/_participation:0|id": "199",
"conformance-ehrbase.de.v0/context/_participation:0|id_scheme": "HOSPITAL-NS",
"conformance-ehrbase.de.v0/context/_participation:0|id_namespace": "HOSPITAL-NS",
"conformance-ehrbase.de.v0/context/start_time": "2021-12-21T14:19:31.649613+01:00",
"conformance-ehrbase.de.v0/context/_end_time": "2021-12-21T15:19:31.649613+01:00",
"conformance-ehrbase.de.v0/context/_location": "2021-12-21T15:19:31.649613+01:00",
"conformance-ehrbase.de.v0/context/setting|code": "238",
"conformance-ehrbase.de.v0/context/setting|value": "other care",
"conformance-ehrbase.de.v0/context/setting|terminology": "openehr"
}
| Flat Path | Flat type | RM Path | Required | Note |
|---|---|---|---|---|
|
String |
name |
no |
|
|
String |
external_ref.id.value |
no |
|
|
String |
external_ref.id.scheme |
no |
|
|
String |
external_ref.id.namespace |
(yes) |
required if id is set |
|
identifiers |
no |
OBJECT_REF
See RM specification of the EVENT_CONTEXT class.
{
"conformance-ehrbase.de.v0/conformance_section/conformance_instruction/_guideline_id|type": "GUIDELINE",
"conformance-ehrbase.de.v0/conformance_section/conformance_instruction/_guideline_id|namespace": "HOSPITAL-NS",
"conformance-ehrbase.de.v0/conformance_section/conformance_instruction/_guideline_id|id": "3445",
"conformance-ehrbase.de.v0/conformance_section/conformance_instruction/_guideline_id|id_scheme": "HOSPITAL-NS"
}
| Flat Path | Flat type | RM Path | Required | Note |
|---|---|---|---|---|
|
String |
type |
yes |
|
|
String |
id.value |
yes |
|
|
String |
id.scheme |
yes |
|
|
String |
namespace |
yes |
INTERVAL_EVENT
See RM specification of the INTERVAL_EVENT class.
{
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_quantity|magnitude": 65.9,
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_quantity|unit": "unit",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/width": "P30D",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/math_function|code": "146",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/math_function|value": "mean",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/math_function|terminology": "openehr"
}
{
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_quantity|magnitude": 65.9,
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_quantity|unit": "unit",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0|sample_count": 5,
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/width": "P30D",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/math_function|code": "146",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/math_function|value": "mean",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/math_function|terminology": "openehr"
}
| Flat Path | Flat type | RM Path | Required | Note |
|---|---|---|---|---|
|
width |
yes |
||
|
math_function |
yes |
||
|
INTEGER |
sample_count |
no |
POINT_EVENT
See RM specification of the EVENT_CONTEXT class.
{
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_text": "DV_TEXT value",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/time": "2021-12-21T16:02:58.0094262+01:00"
}
| Flat Path | Flat type | RM Path | Required | Note |
|---|---|---|---|---|
|
time |
yes |
PARTY_PROXY
See RM specification of the PARTY_PROXY class.
See PARTY_SELF, PARTY_IDENTIFIED and PARTY_RELATED.
PARTY_SELF
See RM specification of the PARTY_SELF class.
{
"ctx/composer_self": true,
"conformance-ehrbase.de.v0/composer|id": "1234-5678",
"conformance-ehrbase.de.v0/composer|id_scheme": "UUID",
"conformance-ehrbase.de.v0/composer|id_namespace": "EHR.NETWORK"
}
| Flat Path | Flat type | RM Path | Required | Note |
|---|---|---|---|---|
|
String |
external_ref.id.value |
no |
|
|
Integer |
external_ref.id.scheme |
no |
|
|
String |
external_ref.id.namespace |
(yes) |
required if id is set |
PARTY_IDENTIFIED
See RM specification of the PARTY_IDENTIFIED class.
{
"conformance-ehrbase.de.v0/composer|name": "Silvia Blake"
}
{
"conformance-ehrbase.de.v0/composer|name": "Silvia Blake",
"conformance-ehrbase.de.v0/composer|id": "1234-5678",
"conformance-ehrbase.de.v0/composer|id_scheme": "UUID",
"conformance-ehrbase.de.v0/composer|id_namespace": "EHR.NETWORK",
"conformance-ehrbase.de.v0/composer/_identifier:0|id": "122",
"conformance-ehrbase.de.v0/composer/_identifier:0|issuer": "issuer",
"conformance-ehrbase.de.v0/composer/_identifier:0|assigner": "assigner",
"conformance-ehrbase.de.v0/composer/_identifier:0|type": "type"
}
| Flat Path | Flat type | RM Path | Required | Note |
|---|---|---|---|---|
|
String |
name |
no |
|
|
String |
external_ref.id.value |
no |
|
|
Integer |
external_ref.id.scheme |
no |
|
|
String |
external_ref.id.namespace |
(yes) |
required if id is set |
|
identifiers |
no |
PARTY_RELATED
See RM specification of the PARTY_RELATED class.
{
"conformance-ehrbase.de.v0/composer|name": "Silvia Blake",
"conformance-ehrbase.de.v0/composer/relationship|code": "10",
"conformance-ehrbase.de.v0/composer/relationship|value": "mother",
"conformance-ehrbase.de.v0/composer/relationship|terminology": "openehr"
}
{
"conformance-ehrbase.de.v0/composer|name": "Silvia Blake",
"conformance-ehrbase.de.v0/composer|id": "1234-5678",
"conformance-ehrbase.de.v0/composer|id_scheme": "UUID",
"conformance-ehrbase.de.v0/composer|id_namespace": "EHR.NETWORK",
"conformance-ehrbase.de.v0/composer/relationship|code": "10",
"conformance-ehrbase.de.v0/composer/relationship|value": "mother",
"conformance-ehrbase.de.v0/composer/relationship|terminology": "openehr",
"conformance-ehrbase.de.v0/composer/_identifier:0|id": "122",
"conformance-ehrbase.de.v0/composer/_identifier:0|issuer": "issuer",
"conformance-ehrbase.de.v0/composer/_identifier:0|assigner": "assigner",
"conformance-ehrbase.de.v0/composer/_identifier:0|type": "type"
}
| Flat Path | Flat type | RM Path | Required | Note |
|---|---|---|---|---|
|
String |
name |
no |
|
|
String |
external_ref.id.value |
no |
|
|
Integer |
external_ref.id.scheme |
no |
|
|
String |
external_ref.id.namespace |
(yes) |
required if id is set |
|
identifiers |
no |
||
|
relationship |
(yes) |
DV_TEXT
See RM specification of the DV_TEXT class.
{
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_text": "DV_TEXT value"
}
{
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_text": "DV_TEXT value",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_text|formatting": "plain",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_text/_language|code": "en",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_text/_language|terminology": "ISO_639-1",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_text/_language|preferred_term": "English",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_text/_encoding|code": "UTF-8",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_text/_encoding|terminology": "IANA_character-sets",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_text/_mapping:0|match": "=",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_text/_mapping:0/target|terminology": "SNOMED-CT",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_text/_mapping:0/target|code": "21794005",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_text/_mapping:0/purpose|terminology": "openehr",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_text/_mapping:0/purpose|code": "671",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_text/_mapping:0/purpose|value": "research study"
}
| Flat Path | Flat type | RM Path | Required | Note |
|---|---|---|---|---|
|
String |
value |
yes |
|
|
String |
formatting |
no |
|
|
language |
no |
||
|
encoding |
no |
||
|
mappings |
no |
CODE_PHRASE
See RM specification of the CODE_PHRASE class.
{
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_text/_language|code": "en",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_text/_language|terminology": "ISO_639-1"
}
{
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_text/_language|code": "en",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_text/_language|terminology": "ISO_639-1",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_text/_language|preferred_term": "English"
}
| Flat Path | Flat type | RM Path | Required | Note |
|---|---|---|---|---|
|
String |
code_string |
yes |
|
|
String |
terminology_id.value |
yes |
|
|
String |
preferred_term |
no |
TERM_MAPPING
See RM specification of the TERM_MAPPING class.
{
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_text/_mapping:0|match": "=",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_text/_mapping:0/target|terminology": "SNOMED-CT",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_text/_mapping:0/target|code": "21794005"
}
{
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_text/_mapping:0|match": "=",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_text/_mapping:0/target|terminology": "SNOMED-CT",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_text/_mapping:0/target|code": "21794005",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_text/_mapping:0/purpose|terminology": "openehr",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_text/_mapping:0/purpose|code": "671",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_text/_mapping:0/purpose|value": "research study"
}
| Flat Path | Flat type | RM Path | Required | Note |
|---|---|---|---|---|
|
String |
match |
yes |
|
|
target |
yes |
||
|
purpose |
no |
DV_CODED_TEXT
See RM specification of the DV_CODED_TEXT class.
{
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_coded_text|value": "term1",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_coded_text|code": "at0006",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_coded_text|terminology": "local"
}
{
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_coded_text|value": "term1",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_coded_text|code": "at0006",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_coded_text|terminology": "local",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_coded_text|formatting": "plain",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_coded_text/_language|code": "en",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_coded_text/_language|terminology": "ISO_639-1",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_coded_text/_language|preferred_term": "English",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_coded_text/_encoding|code": "UTF-8",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_coded_text/_encoding|terminology": "IANA_character-sets",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_coded_text/_mapping:0|match": "=",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_coded_text/_mapping:0/target|terminology": "SNOMED-CT",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_coded_text/_mapping:0/target|code": "21794005",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_coded_text/_mapping:0/purpose|terminology": "openehr",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_coded_text/_mapping:0/purpose|code": "671",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_coded_text/_mapping:0/purpose|value": "research study"
}
| Flat Path | Flat type | RM Path | Required | Note |
|---|---|---|---|---|
|
String |
defining_code.code_string |
yes |
|
|
String |
value |
(yes) |
only required for external terminologies |
|
String |
defining_code.terminology_id.value |
(yes) |
only required for external terminologies |
|
String |
formatting |
no |
|
|
language |
no |
||
|
encoding |
no |
||
|
mappings |
no |
DV_ORDINAL
See RM specification of the DV_ORDINAL class.
{
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_ordinal|code": "at0015",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_ordinal|value": "value1",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_ordinal|ordinal": 1
}
{
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_ordinal|code": "at0015",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_ordinal|value": "value1",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_ordinal|ordinal": 1,
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_ordinal/_normal_range/lower|code": "at0015",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_ordinal/_normal_range/lower|value": "value1",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_ordinal/_normal_range/lower|ordinal": 1,
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_ordinal/_normal_range/upper|code": "at0015",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_ordinal/_normal_range/upper|value": "value1",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_ordinal/_normal_range/upper|ordinal": 1,
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_ordinal/_other_reference_ranges:0/lower|code": "at0016",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_ordinal/_other_reference_ranges:0/lower|value": "value2",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_ordinal/_other_reference_ranges:0/lower|ordinal": 2,
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_ordinal/_other_reference_ranges:0|upper_unbounded": true,
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_ordinal/_other_reference_ranges:0|upper_included": false,
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_ordinal/_other_reference_ranges:0/meaning": "high"
}
| Flat Path | Flat type | RM Path | Required | Note |
|---|---|---|---|---|
|
String |
symbol.defining_code.code_string |
Yes |
|
|
String |
symbol.value |
(Yes) |
my be left out if symbol is defined in template |
|
Integer |
value |
(Yes) |
my be left out if symbol is defined in template |
|
DV_INTERVAL <DV_ORDINAL> |
normal_range |
no |
|
|
REFERENCE_RANGE <DV_ORDINAL> |
|
no |
DV_BOOLEAN
See RM specification of the DV_BOOLEAN class.
{
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_boolean": true
}
| Flat Path | Flat type | RM Path | Required | Note |
|---|---|---|---|---|
Boolean |
value |
Yes |
DV_URI
See RM specification of the DV_URI class.
{
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_uri": "https://www.google.com/"
}
| Flat Path | Flat type | RM Path | Required | Note |
|---|---|---|---|---|
String |
value |
Yes |
DV_EHR_URI
See RM specification of the DV_EHR_URI class.
{
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_ehr_uri": "ehr://766b3873-0762-4921-91e2-838c8546d47f"
}
| Flat Path | Flat type | RM Path | Required | Note |
|---|---|---|---|---|
String |
value |
Yes |
DV_IDENTIFIER
See RM specification of the DV_QUANTITY class.
{
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_identifier|id": "A123"
}
{
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_identifier|id": "A123",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_identifier|issuer": "Issuer",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_identifier|assigner": "Assigner",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_identifier|type": "Prescription"
}
| Flat Path | Flat type | RM Path | Required | Note |
|---|---|---|---|---|
|
String |
id |
Yes |
For the input |id might be left out. |
|
String |
issuer |
no |
|
|
String |
assigner |
no |
|
|
String |
type |
no |
DV_QUANTITY
See RM specification of the DV_QUANTITY class.
{
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_quantity|magnitude": 65.9,
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_quantity|unit": "unit"
}
{
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_quantity|magnitude": 65.9,
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_quantity|magnitude_status": "~",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_quantity|normal_status": "N",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_quantity|accuracy": 50.5,
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_quantity|accuracy_is_percent": true,
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_quantity|precision": 1,
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_quantity|unit": "unit",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_quantity|units_system": "units_system",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_quantity|units_display_name": "units_display_name",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_quantity/_normal_range/lower|magnitude": 20.5,
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_quantity/_normal_range/lower|unit": "unit",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_quantity/_normal_range/upper|magnitude": 66.6,
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_quantity/_normal_range/upper|unit": "unit",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_quantity/_other_reference_ranges:0/lower|magnitude": 70.5,
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_quantity/_other_reference_ranges:0/lower|unit": "unit",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_quantity/_other_reference_ranges:0/upper|magnitude": 77.6,
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_quantity/_other_reference_ranges:0/upper|unit": "unit",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_quantity/_other_reference_ranges:0/meaning|value": "very high",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_quantity/_other_reference_ranges:0/meaning|code": "260360000",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_quantity/_other_reference_ranges:0/meaning|terminology": "SNOMED-CT"
}
| Flat Path | Flat type | RM Path | Required | Note |
|---|---|---|---|---|
|
String |
magnitude |
yes |
|
|
Real |
unit |
yes |
|
|
String |
magnitude_status |
no |
ValueSet (",>,>=,<,<=,~) |
|
String |
normal_status |
no |
ValueSet normal_status |
|
Real |
accuracy |
no |
|
|
Boolean |
accuracy_is_percent |
no |
|
|
DV_INTERVAL <DV_QUANTITY> |
normal_range |
no |
|
|
REFERENCE_RANGE <DV_QUANTITY> |
|
no |
DV_PROPORTION
See RM specification of the DV_PROPORTION class.
{
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_proportion|numerator": 20.5,
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_proportion|denominator": 12.4,
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_proportion|type": 0
}
{
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_proportion|numerator": 20.5,
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_proportion|denominator": 12.4,
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_proportion|type": 0,
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_proportion": 1.6532258064516128,
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_proportion|magnitude_status": "~",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_proportion|normal_status": "N",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_proportion|accuracy": 50.5,
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_proportion|accuracy_is_percent": true,
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_proportion|precision": 1,
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_proportion/_normal_range/lower|numerator": 20.5,
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_proportion/_normal_range/lower|denominator": 12.4,
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_proportion/_normal_range/lower|type": 0,
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_proportion/_normal_range/lower": 1.6532258064516128,
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_proportion/_normal_range/upper|numerator": 25.5,
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_proportion/_normal_range/upper|denominator": 12.4,
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_proportion/_normal_range/upper|type": 0,
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_proportion/_normal_range/upper": 2.0564516129032255,
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_proportion/_other_reference_ranges:0/lower|numerator": 20.5,
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_proportion/_other_reference_ranges:0/lower|denominator": 18.4,
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_proportion/_other_reference_ranges:0/lower|type": 0,
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_proportion/_other_reference_ranges:0/lower": 1.1141304347826089,
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_proportion/_other_reference_ranges:0/upper|numerator": 25.5,
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_proportion/_other_reference_ranges:0/upper|denominator": 12.4,
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_proportion/_other_reference_ranges:0/upper|type": 0,
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_proportion/_other_reference_ranges:0/upper": 2.0564516129032255,
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_proportion/_other_reference_ranges:0/meaning": "high"
}
| Flat Path | Flat type | RM Path | Required | Note |
|---|---|---|---|---|
|
Real |
numerator |
yes |
|
|
Real |
denominator |
yes |
|
|
Integer |
type |
yes |
ValueSet proportion_kind |
Real |
magnitude |
no |
calculated on output |
|
|
String |
magnitude_status |
no |
ValueSet (",>,>=,<,<=,~) |
|
String |
normal_status |
no |
ValueSet normal_status |
|
DV_INTERVAL <DV_PROPORTION> |
normal_range |
no |
|
|
REFERENCE_RANGE <DV_PROPORTION> |
|
no |
DV_COUNT
See RM specification of the DV_COUNT class.
{
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_count": 7
}
{
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_count": 7,
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_count|magnitude_status": "~",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_count|normal_status": "N",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_count|accuracy": 50.5,
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_count|accuracy_is_percent": true,
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_count/_normal_range/lower": 1,
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_count/_normal_range/upper": 8,
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_count/_other_reference_ranges:0/lower": 8,
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_count/_other_reference_ranges:0/upper": 10,
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_count/_other_reference_ranges:0/meaning": "high"
}
| Flat Path | Flat type | RM Path | Required | Note |
|---|---|---|---|---|
Integer |
magnitude |
Yes |
||
|
String |
magnitude_status |
no |
ValueSet (",>,>=,<,<=,~) |
|
String |
normal_status |
no |
ValueSet normal_status |
|
DV_INTERVAL <DV_COUNT> |
normal_range |
no |
|
|
REFERENCE_RANGE <DV_COUNT> |
|
no |
DV_DATE
See RM specification of the DV_DATE class.
{
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_date": "2022-01-12"
}
{
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_date": "2022-01-12",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_date|magnitude_status": "~",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_date|normal_status": "N",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_date/_accuracy": "P2D",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_date/_normal_range/lower": "2022-01-12",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_date/_normal_range/upper": "2022-02-12",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_date/_other_reference_ranges:0/lower": "2022-02-12",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_date/_other_reference_ranges:0/upper": "2022-03-12",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_date/_other_reference_ranges:0/meaning": "high"
}
| Flat Path | Flat type | RM Path | Required | Note |
|---|---|---|---|---|
String |
value |
Yes |
ISO8601 date |
|
|
accuracy |
no |
||
|
String |
magnitude_status |
no |
ValueSet (",>,>=,<,<=,~) |
|
String |
normal_status |
no |
ValueSet normal_status |
|
DV_INTERVAL <DV_DATE> |
normal_range |
no |
|
|
REFERENCE_RANGE <DV_DATE> |
|
no |
DV_DATE_TIME
See RM specification of the DV_DATE class.
{
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_date_time": "2022-01-12T13:22:34.000868+01:00"
}
{
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_date_time": "2022-01-12T13:22:34.000868+01:00",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_date_time|magnitude_status": "~",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_date_time|normal_status": "N",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_date_time/_accuracy": "P2DT9H52M",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_date_time/_normal_range/lower": "2022-01-12T13:22:34.000868+01:00",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_date_time/_normal_range/upper": "2022-02-12T13:22:34.000868+01:00",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_date_time/_other_reference_ranges:0/lower": "2022-02-12T13:22:34.000868+01:00",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_date_time/_other_reference_ranges:0/upper": "2022-03-12T13:22:34.000868+01:00",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_date_time/_other_reference_ranges:0/meaning": "high"
}
| Flat Path | Flat type | RM Path | Required | Note |
|---|---|---|---|---|
String |
value |
Yes |
ISO8601 date |
|
|
accuracy |
no |
||
|
String |
magnitude_status |
no |
ValueSet (",>,>=,<,<=,~) |
|
String |
normal_status |
no |
ValueSet normal_status |
|
DV_INTERVAL <DV_DATE_TIME> |
normal_range |
no |
|
|
REFERENCE_RANGE <DV_DATE_TIME> |
|
no |
DV_TIME
See RM specification of the DV_DATE class.
{
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_date": "2022-01-12"
}
{
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_time": "13:22:34.000868+01:00",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_time|magnitude_status": "~",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_time|normal_status": "N",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_time/_accuracy": "PT9H52M",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_time/_normal_range/lower": "13:22:34.000868+01:00",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_time/_normal_range/upper": "14:22:34.000868+01:00",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_time/_other_reference_ranges:0/lower": "14:10:34.000868+01:00",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_time/_other_reference_ranges:0/upper": "15:22:34.000868+01:00",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_time/_other_reference_ranges:0/meaning": "high"
}
| Flat Path | Flat type | RM Path | Required | Note |
|---|---|---|---|---|
String |
value |
Yes |
ISO8601 date |
|
|
accuracy |
no |
||
|
String |
magnitude_status |
no |
ValueSet (",>,>=,<,<=,~) |
|
String |
normal_status |
no |
ValueSet normal_status |
|
DV_INTERVAL <DV_TIME> |
normal_range |
no |
|
|
REFERENCE_RANGE <DV_TIME> |
|
no |
DV_DURATION
See RM specification of the DV_DURATION class.
{
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_duration": "P2DT11H33M"
}
{
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_duration": "P2DT11H33M",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_duration|magnitude_status": "~",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_duration|normal_status": "N",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_duration|accuracy": 50.5,
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_duration|accuracy_is_percent": true,
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_duration/_normal_range/lower": "P2DT11H33M",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_duration/_normal_range/upper": "P2DT12H33M",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_duration/_other_reference_ranges:0/lower": "P2DT11H33M",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_duration/_other_reference_ranges:0/upper": "P2DT15H33M",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_duration/_other_reference_ranges:0/meaning": "high"
}
| Flat Path | Flat type | RM Path | Required | Note |
|---|---|---|---|---|
String |
value |
Yes |
ISO8601 duration |
|
|
Real |
accuracy |
no |
|
accuracy_is_percent |
Boolean |
accuracy_is_percent |
no |
|
|
String |
magnitude_status |
no |
ValueSet (",>,>=,<,<=,~) |
|
String |
normal_status |
no |
ValueSet normal_status |
|
DV_INTERVAL <DV_DURATION> |
normal_range |
no |
|
|
REFERENCE_RANGE <DV_DURATION> |
|
no |
REFERENCE_RANGE
See RM specification of the REFERENCE_RANGE class.
{
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_quantity/_other_reference_ranges:0/lower|magnitude": 70.5,
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_quantity/_other_reference_ranges:0/lower|unit": "unit",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_quantity/_other_reference_ranges:0/upper|magnitude": 77.6,
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_quantity/_other_reference_ranges:0/upper|unit": "unit",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_quantity/_other_reference_ranges:0/meaning|value": "high"
}
{
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_quantity/_other_reference_ranges:0/lower|magnitude": 70.5,
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_quantity/_other_reference_ranges:0/lower|unit": "unit",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_quantity/_other_reference_ranges:0|upper_unbounded": true,
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_quantity/_other_reference_ranges:0|upper_included": false,
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_quantity/_other_reference_ranges:0/meaning|value": "very high",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_quantity/_other_reference_ranges:0/meaning|code": "260360000",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_quantity/_other_reference_ranges:0/meaning|terminology": "SNOMED-CT",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_quantity/_other_reference_ranges:1|lower_unbounded": true,
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_quantity/_other_reference_ranges:1|lower_included": false,
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_quantity/_other_reference_ranges:1/upper|magnitude": 77.6,
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_quantity/_other_reference_ranges:1/upper|unit": "unit",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_quantity/_other_reference_ranges:1/meaning|value": "very high",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_quantity/_other_reference_ranges:1/meaning|code": "260360000",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_quantity/_other_reference_ranges:1/meaning|terminology": "SNOMED-CT"
}
| Flat Path | Flat type | RM Path | Required | Note |
|---|---|---|---|---|
|
T |
range.lower |
no |
|
|
T |
range.upper |
no |
|
|
Boolean |
range.lower_unbounded |
no |
defaults to false |
|
Boolean |
range.upper_unbounded |
no |
defaults to false |
|
Boolean |
range.lower_included |
no |
defaults to true |
|
Boolean |
range.upper_included |
no |
defaults to true |
\meaning |
meaning |
yes |
DV_PARSABLE
See RM specification of the DV_PARSABLE class.
{
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_parsable": "Formal instructions on carrying out the procedure...",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_parsable|formalism": "GLIF 1.0"
}
{
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_parsable": "Formal instructions on carrying out the procedure...",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_parsable|formalism": "GLIF 1.0",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_parsable/_language|code": "en",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_parsable/_language|terminology": "ISO_639-1",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_parsable/_charset|code": "UTF-8",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_parsable/_charset|terminology": "IANA_character-sets"
}
| Flat Path | Flat type | RM Path | Required | Note |
|---|---|---|---|---|
|
String |
value |
Yes |
|
|
String |
formalism |
Yes |
|
|
charset |
no |
||
|
language |
no |
DV_MULTIMEDIA
See RM specification of the DV_MULTIMEDIA class.
{
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_multimedia": "http://med.tube.com/sample",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_multimedia|mediatype": "video/H261",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_multimedia|size": 504903212
}
{
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_multimedia": "http://med.tube.com/sample",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_multimedia|mediatype": "video/H261",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_multimedia|size": 504903212,
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_multimedia|compression_algorithm": "zlib",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_multimedia|alternatetext": "alternate text",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_multimedia|integrity_check": "b90360558e5420cef47015b1afbd70a156f940afa470b0515f95eacc2edcef6a",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_multimedia|integrity_check_algorithm": "SHA-256",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_multimedia/_thumbnail|data": "Z2hnZ2pnamdnag==",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_multimedia/_thumbnail|mediatype": "image/png",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_multimedia/_thumbnail|size": 504,
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_multimedia/_language|code": "en",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_multimedia/_language|terminology": "ISO_639-1",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_multimedia/_charset|code": "UTF-8",
"conformance-ehrbase.de.v0/conformance_section/conformance_observation/any_event:0/dv_multimedia/_charset|terminology": "IANA_character-sets"
}
| Flat Path | Flat type | RM Path | Required | Note |
|---|---|---|---|---|
String |
uri.value |
no |
||
|
String |
media_type.code_string |
Yes |
ValueSet (IANA_media-types) |
|
Integer |
size |
Yes |
|
|
String |
alternate_text |
no |
|
|
String |
compression_algorithm.code_string |
no |
ValueSet (openehr_compression_algorithms) |
|
String |
integrity_check_algorithm |
no |
ValueSet (openehr_integrity_check_algorithms) |
|
String |
integrity_check |
no |
|
|
String |
dta |
no |
|
|
thumbnail |
no |
||
|
charset |
no |
||
|
language |
no |
DV_INTERVAL
See RM specification of the DV_INTERVAL class.
{
"conformance-ehrbase.de.v0/conformance_section/conformance_interval/any_event:0/interval_dv_quantity/lower|magnitude": 72.83,
"conformance-ehrbase.de.v0/conformance_section/conformance_interval/any_event:0/interval_dv_quantity/lower|unit": "Unit",
"conformance-ehrbase.de.v0/conformance_section/conformance_interval/any_event:0/interval_dv_quantity/upper|magnitude": 80.83,
"conformance-ehrbase.de.v0/conformance_section/conformance_interval/any_event:0/interval_dv_quantity/upper|unit": "Unit"
}
{
"conformance-ehrbase.de.v0/conformance_section/conformance_interval/any_event:0/interval_dv_quantity/lower|magnitude": 72.83,
"conformance-ehrbase.de.v0/conformance_section/conformance_interval/any_event:0/interval_dv_quantity/lower|unit": "Unit",
"conformance-ehrbase.de.v0/conformance_section/conformance_interval/any_event:0/interval_dv_quantity|lower_included": false,
"conformance-ehrbase.de.v0/conformance_section/conformance_interval/any_event:0/interval_dv_quantity|upper_unbounded": true,
"conformance-ehrbase.de.v0/conformance_section/conformance_interval/any_event:0/interval_dv_quantity|upper_included": false
}
| Flat Path | Flat type | RM Path | Required | Note |
|---|---|---|---|---|
|
T |
lower |
no |
|
|
T |
upper |
no |
|
|
BOOLEAN |
|
no |
defaults to false. only in output if true |
|
BOOLEAN |
upper_unbounded |
no |
defaults to false, only in output if true |
|
BOOLEAN |
lower_included |
no |
defaults to true. only in output if false |
|
BOOLEAN |
upper_included |
no |
defaults to true. only in output if false |